When preparing to import your SketchUp Model into Revit using the Trimble SketchUp Importer for Revit, the following modeling best practices can help make sure parts of your model convert to Revit elements and prevent conversion failures.
Basic Preparation
Group all geometry into components. Never leave loose, ungrouped geometry at the model root level.
Classify components using proper IFC classes inside the Entity Info panel.
Ensure every component is a sealed 3D solid displaying a Volume in the Entity Info panel.
Overlap doors and windows onto their host wall by at least 10 mm or 0.4 inches.
Assign clean, descriptive component names and organize model layers using tags.
Prior to export, purge unused styles, components, and materials by selecting Window > Model Info > Statistics > Purge Unused. Cleaning unused statistics speeds up conversion processing.
Preparing Faces and Surfaces
Revit requires clear surface orientation to evaluate geometry thickness, finishes, and boundaries. SketchUp geometry consists of front faces and back faces. To help make sure your faces convert as expected, follow these guidelines:
Front Faces Pointing Outward – Align front faces to point toward the exterior of all solid shapes. Back faces placed on exterior boundaries can cause issues like wall finish misassignments, ceiling build failures, and roof conversion rejections.
Wall Finish Normals – The importer determines interior and exterior finish assignments based on face normals relative to the wall baseline. If a finish lands on the wrong side of a wall, reverse the face orientation in SketchUp.
Clean Geometry Boundaries – Remove self-intersecting loops, non-planar faces, and zero-thickness sliver edges (under 0.8 mm) prior to conversion.
Element-Specific Modeling Specifications
The following table outlines specifications for entity and element types to help make sure each type converts during the import process.
Element or Entity Type | Required IFC Class | Definition and Best Practices | Failure Outcome |
|---|---|---|---|
Walls |
| Vertical solids with true thickness (minimum 30 mm). Curved walls must be true arcs.Curved walls can’t host doors or windows. | Converts to a Generic Model loadable family. |
Doors and Windows |
| Must overlap the host wall body by at least 10 mm. Include an optional | Places an unhosted family at source coordinates without cutting an opening. |
Floors and Slabs |
| Flat solids with a horizontal top face defining the perimeter boundary. | Converts to a Generic Model loadable family. |
Ceilings |
| Flat solids with horizontal, downward-facing front faces defining the bottom perimeter boundary. Rims, steps, and bands smaller than 50 mm are automatically folded into the main ceiling plate. | Converts to a Generic Model loadable family. |
Roofs |
| Single closed solid slab of uniform thickness without interior face holes or mixed face winding. | Imports as a mesh inside the Roofs category. |
Curtain Walls |
| Surface assemblies or modular frames containing | Converts to a Generic Model assembly. |
Modeling Practices to Avoid
What to Avoid | What Can Happen |
|---|---|
Leaving loose faces or ungrouped edges | Geometry is skipped for native elements or merged into an unnamed Generic Model. |
Deeply nested component hierarchies | Generates excessive nested family definitions and increases conversion time. |
Mirrored or non-uniformly scaled component copies | Bakes scale into geometry during conversion, breaking family instance reuse and generating separate shape instances formatted as |
Leaving CAD imports, guides, text, or section planes in model | Guides, text, and section planes are dropped silently; dimensions import as Generic Models. |
Modeling geometry far from the SketchUp origin | Causes coordinate precision loss and display clipping errors inside Revit. |